ASD/LRFD Conversion

Converting between Allowable Stress Design and Load & Resistance Factor Design

Quick Navigation: Design Methods


ASD
Allowable Stress

LRFD
Load & Resistance

ASD/LRFD
Conversion

Nom vs Ult
Comparison

Nominal
Explained

Ultimate
Explained

Directional
Kd Factor

ASD to LRFD Conversion Overview

Converting between Allowable Stress Design (ASD) and Load and Resistance Factor Design (LRFD) is frequently necessary when working with mixed design methods, evaluating existing structures, or converting component ratings for use in structural analysis.

The key concept: Both methods calculate the same wind pressures using identical ASCE 7 equations. The difference is in how those pressures are applied in load combinations and member design.

Same Pressure Calculation

ASD and LRFD use identical ASCE 7 equations for wind pressure. The same p (psf) value is calculated - only its application differs.

Load Factor Conversion

ASD uses 0.6W in load combinations, LRFD uses 1.0W. The ratio is approximately 1.6 for conversion purposes.

Resistance Side Differs

ASD uses allowable stresses (Fy/FS), LRFD uses φRn. Different safety philosophy achieves similar reliability.

Component Ratings

Architectural components (windows, doors) typically rated in ASD (DP values). Converting to LRFD requires understanding load factor relationships.

Load Factor Conversion Table

Conversion Direction Formula Example
ASD → LRFD WLRFD ≈ 1.6 × WASD WASD = 25 psf → WLRFD ≈ 40 psf
LRFD → ASD WASD ≈ WLRFD / 1.6 WLRFD = 40 psf → WASD = 25 psf
Component DP Rating → LRFD Required DP ≈ WLRFD / 1.6 WLRFD = 64 psf → Need DP-40 rating

Why 1.6 Conversion Factor?

The 1.6 factor comes from the ratio of LRFD to ASD load factors:

  • ASD wind combination: D + 0.6W
  • LRFD wind combination: 1.2D + 1.0W (or 0.9D + 1.0W for uplift)
  • Approximate conversion: 1.0W / 0.6W ≈ 1.6
  • Note: This is simplified - exact conversion depends on D/W ratio

Step-by-Step Conversion Examples

Example 1: Converting Component DP Rating for LRFD Use

Problem: You have a window rated DP-50 (ASD rating). Can it be used in an LRFD design where the calculated wind pressure is 75 psf?

Given:
Component DP rating = 50 psf (ASD nominal)
LRFD calculated pressure = 75 psf (strength level)

Step 1: Convert LRFD pressure to ASD equivalent
ASD equivalent = 75 psf / 1.6 = 46.9 psf

Step 2: Compare to component rating
Component DP-50 > 46.9 psf required

Answer: ✓ YES - DP-50 window is adequate
(50 psf > 46.9 psf, with 6% margin)

Example 2: ASD Beam Design with LRFD Wind Loads

Problem: Structural analysis provided LRFD factored loads. You want to check beam using ASD method.

Given:
LRFD factored wind load = 1,200 lb/ft (from 1.2D + 1.0W)
Dead load D = 400 lb/ft

Step 1: Back-calculate unfactored wind load
1,200 = 1.2(400) + 1.0(W)
1,200 = 480 + W
W = 720 lb/ft

Step 2: Apply ASD load combination
wASD = D + 0.6W
wASD = 400 + 0.6(720)
wASD = 832 lb/ft

Use 832 lb/ft for ASD beam design

Example 3: Converting Existing ASD Design to LRFD

Problem: Evaluate existing building designed using ASD with new LRFD analysis.

Given:
Existing design: ASD with p = 30 psf wind pressure
Original: D + 0.6W combination

Step 1: The wind pressure remains the same
p = 30 psf (this doesn't change)

Step 2: Apply LRFD load combinations
Check: 1.2D + 1.0W (with p = 30 psf)
Check: 0.9D + 1.0W (uplift, with p = 30 psf)

Step 3: Verify with LRFD resistance
Use φRn instead of allowable stresses

Note: Members designed for ASD may have different
capacity ratios under LRFD due to φ factors

Important Conversion Notes

  • Wind pressure (p in psf) is the SAME for ASD and LRFD
  • Load factors differ (0.6W vs 1.0W)
  • Resistance calculations differ (allowable vs factored)
  • 1.6 factor is approximate - exact conversion depends on D/W ratio
  • Components rated in ASD can be used with LRFD by converting

Detailed ASD ↔ LRFD Comparison

Design Aspect ASD Approach LRFD Approach Conversion
Wind Pressure Calc p = qh[(GCp)-(GCpi)] p = qh[(GCp)-(GCpi)] SAME - no conversion needed
Load Combination D + 0.6W 1.2D + 1.0W Load factor ratio ≈ 1.6
Uplift Combination 0.6D + 0.6W 0.9D + 1.0W Depends on D/W ratio
Steel Flexure fb ≤ Fb = 0.6Fy Mu ≤ φMn (φ=0.90) Different equations
Component Rating DP-40 = 40 psf nominal Convert: 40 × 1.6 ≈ 64 psf Multiply by 1.6
Terminology "Nominal" wind loads "Ultimate" wind loads Same pressure, different name

When Conversion is Necessary

Component Selection

Architectural components (windows, doors, curtain walls) are typically rated in ASD (DP values). Must convert when using with LRFD structural analysis.

Mixed Design

When main structure uses LRFD but components or connections designed using ASD, conversion ensures compatibility.

Existing Building Evaluation

Evaluating or modifying existing ASD-designed structures using modern LRFD analysis software requires proper conversion.

Code Compliance

Jurisdictions may require specific design method. Conversion allows using available design resources regardless of method.

Common Conversion Mistakes to Avoid

WRONG: Multiplying wind pressure (psf) by 1.6 to convert ASD to LRFD
RIGHT: Wind pressure stays THE SAME. Only load factors and resistance factors change.

WRONG: Using DP-40 component with 64 psf LRFD pressure directly
RIGHT: Convert LRFD pressure to ASD equivalent (64/1.6 = 40 psf), then compare to DP rating

WRONG: Assuming 1.6 factor applies to all situations equally
RIGHT: Recognize 1.6 is approximate - exact conversion depends on dead-to-wind load ratio

Conversion Checklist

  • ✓ Calculate wind pressure using ASCE 7 (same for both methods)
  • ✓ Identify which design method is required
  • ✓ Apply correct load factors (0.6W for ASD, 1.0W for LRFD)
  • ✓ Convert component ratings using ≈1.6 factor when needed
  • ✓ Use appropriate resistance equations for each method
  • ✓ Document conversion methodology for reviewer
  • ✓ Verify final design meets code requirements